Specification
Connectors1: |
SC, FC, ST, LC, … |
Optical fiber type |
Multimode |
Single mode |
Polishing technology |
PC |
UPC |
APC |
Insertion Loss (IL) |
≤ 0.5 dB |
≤ 0.25 dB |
≤ 0.50 dB |
Return Loss (RL) |
≥ 30 dB |
≥ 50 dB |
≥ 60 dB |
Repeatability |
≤ 0.2 dB |
≤ 0.2 dB |
≤ 0.2 dB |
|
Optical fiber: |
Multimode |
Single mode |
Core/MFD (µm) |
50±2.5 |
62.5±2.5 |
9.2±0.4 @ 1310 nm
10.4±0.8 @ 1550 nm |
Cladding diameter (μm) |
125±1 |
125±1 |
Max. attenuation (dB/km) |
3.5 @ 850 nm
1.5 @ 1300 nm |
0.5 @ 1310 nm
0.4 @ 1550 nm |
Note: 1) other type on request
Flexible EMI Cable Shielding

- High screening efficiency and low surface transfer impedance values with computer optimization and Quality control automation
- Average nominal optical closure 99%, minimum or value 93%
- High expansion and contraction ability with super elasticity
- Plastic Former that can be easily removed and used as a guide
- In addition to facilitating the installation of guide hose, it provides protection of the EMI cable shielding braid form.
- It is produced in 11 different diameters from 3mm to 40mm according cable type
- It is suitable for cable screening in military standards.
Flexible EMI Cable Shielding Cu/Sn* or Cu/Ni*
Wire Size
AWG/mm |
Harness
Tolerance (mm)** |
Coverage % |
Max. weight
(kg/km)*** |
Min Ø |
Max. Ø |
Minimum |
Nominal |
|
38/0,10 |
2,5 |
5,0 |
93,00 |
99,0 |
12,95 |
NOTE:
* With tin or nickel -plated copper wire
** Recommended harness tolerance values. Reference values can be increased or decreased according to the application.